Clear alarm with the Delete key or NC START.
16912
[Channel %1: ] Program control: action %2<ALNX> only possible in reset state
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
This action can only be performed in Reset state.
Example: Program selection through HMI or channel communication (INIT) can only be performed in Reset state.
Reaction:
Alarm display.
Remedy:
Reset or wait until processing is terminated.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16913
[Mode group %1: ] [Channel %2: ] Mode change: action %3<ALNX> not allowed
Parameters:
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name
Explanation:
The change to the desired mode is not permitted. The change can only take place in the Reset state.
Example:
Program processing is halted in AUTO mode by NC Stop. Then there is a mode change to JOG mode (program status
interrupted). From this operating mode, it is only possible to change to AUTO mode and not to MDI mode!
Reaction:
Alarm display.
Remedy:
Either activate the Reset key to reset program processing, or activate the mode in which the program was being processed
previously.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16914
[Mode group %1: ] [Channel %2: ] Mode change: action %3<ALNX> not allowed
Parameters:
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name
Explanation:
Incorrect mode change, e.g.: Auto -> MDIREF.
Reaction:
Alarm display.
Remedy:
Check operation or selected mode.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16915
[Channel %1: ] Action %2<ALNX> not allowed in the current block
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
If traversing blocks are interrupted by asynchronous subroutines, then it must be possible for the interrupted program to
continue (reorganization of block processing) after termination of the asynchronous subroutine.
The 2nd parameter describes which action wanted to interrupt block processing.
Reaction:
Alarm display.
Remedy:
Let the program continue to a reorganized NC block or modify part program.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16916
[Channel %1: ] Repositioning: action %2<ALNX> not allowed in the current state
Parameters:
%1 = Channel number
%2 = Action number/action name