![Siemens SINUMERIK 808D Diagnostic Manual Download Page 91](http://html.mh-extra.com/html/siemens/sinumerik-808d/sinumerik-808d_diagnostic-manual_374970091.webp)
8044
Option for IPO cycle time %1 ms not set
Parameters:
%1 = Impermissible IPO cycle time
Explanation:
The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
- Option-free >= 8ms
- 1. 1st step >= 6ms
- 2. 2nd step >= 4ms
- 3. 3rd step >= 2ms
- 4. 4th step <2ms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Increase IPO cycle time (e.g. via MD10070 $MN_IPO_SYSCLOCK_TIME_RATIO)
Programm
continuation:
Switch control OFF - ON.
8045
'Activation drive integrated ESR' option not set
Explanation:
'Extended stop and retract (ESR)' was activated in the drive, although the corresponding option was not set.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Purchase option
- Deactivate 'Extended stop and retract (ESR)' function in the drive.
Programm
continuation:
Switch control OFF - ON.
8051
Option 'Handwheel on PROFIBUS' not set
Explanation:
The option to operate handwheels on PROFIBUS is not set.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Activate option 'Handwheel on PROFIBUS'
Programm
continuation:
Switch control OFF - ON.
8052
Drive: License %1<DRVLICPANX> with the value %2 is invalid
Parameters:
%1 = Drive, license ID/MLFB
%2 = Drive, license value
Explanation:
The drive option has not been enabled, or the number of enabled drive options was exceeded
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please notify the authorized personnel/service.
- Reset drive option
- Purchase option
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
91