Identifier
NOREADY | BAGREACTIONVIEW
Effects
Mode group ready off: Active fast braking (i.e. with maximum braking current) of the drives in this mode
group, the controller enable of the NC axes involved is deleted.
● Mode group not ready.
Identifier
NOREADY
Effects
Channel ready off: Active fast braking (i.e. with maximum braking current) of the drives in this channel,
the controller enable of the NC axes involved is deleted.
● Channel not ready.
Identifier
NONCSTART
Effects
It is not possible to start a program in this channel.
● NC start inhibit in this channel.
Identifier
NOREFMARK
Effects
The axes in this channel have to be referenced again.
● Re-reference axes in this channel.
Identifier
SETVDI
Effects
VDI interface signal alarm is set.
● Interface signals are set.
Identifier
SHOWALARM
Effects
Alarm is displayed on the HMI.
● Alarm display.
Identifier
STOPBYALARM
Effects
Ramp stop of all channel axes.
● NC stop for alarm.
Identifier
STOPATENDBYALARM
Effects
Stop at end of block.
● NC Stop for alarm at end of block.
System responses
6.1 System reactions to SINUMERIK alarms
Diagnostics Manual
530
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2