Programm
continuation:
Switch control OFF - ON.
26101
Axis %1 drive %2 communication failure
Parameters:
%1 = Axis name, spindle number
%2 = Drive number
Explanation:
For PROFIdrive only:
The drive is not communicating.
Reaction:
Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Axes of this channel must be re-referenced.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Check the bus configuration.
- Check the interface (connector removed, option module inactive, etc.).
Programm
continuation:
Clear alarm with the RESET key. Restart part program
26102
Axis %1 drive %2 sign of life missing
Parameters:
%1 = Axis name, spindle number
%2 = Drive number
Explanation:
For PROFIdrive only:
The sign-of-life cell is no longer being updated by the drive.
Reaction:
Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Axes of this channel must be re-referenced.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Check the cycle settings (recommendation: e.g. MD10062 $MN_POSCTRL_CYCLE_DELAY = 0.0)
- Increase the cycle time if necessary.
- Power-up the drive again.
- Check drive software.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
26105
Drive of axis %1 not found
Parameters:
%1 = Axis name, spindle number
Explanation:
For PROFIdrive only:
The drive configured for the specified axis could not be found. For example, a PROFIBUS slave was configured on the
NC but is not contained in SDB-Type-2000.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2