![Siemens SINUMERIK 808D Diagnostic Manual Download Page 471](http://html.mh-extra.com/html/siemens/sinumerik-808d/sinumerik-808d_diagnostic-manual_374970471.webp)
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check number of contours
- Max. two contours (machined part and blank contours)
- Min. one contour (machined part contour)
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61709
%[[Channel %1: ] Block %2: %]Cutting edge radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check cutting edge radius of the tool in tool management
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61710
%[[Channel %1: ] Block %2: %]Calculation has been canceled
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Calculation has been canceled by PI service; please try again
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61711
%[[Channel %1: ] Block %2: %]Infeed D is larger than the tip width of the tool
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check infeed D in connection with the tip width of the tool in tool management.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61712
%[[Channel %1: ] Block %2: %]Infeed DX or DZ is larger than tip length of tool
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
471