Connector Maintenance: 

 

A daily, weekly and periodic inspection of the connector by competent person is 
recommended. User must establish a regular interval for maintenance as 
determined by the user media and operational environment. 

 

Inspection should include visual checks of the sealing area, handle wear, missing 
or loose components, leak tightness, ease of operation, sufficient lubrication, 
wear, dirt accumulation and damage. 

 

Establish a regular interval for lubrication. The media and environment will be 
determining factors in establishing this interval to prevent dryness and/or 
corrosion. 

 

Difficulty of operation after continual use indicates a need for lubrication or other 
maintenance. 

 

Use only original 

FasTest

 

spare parts that are designed for the application and 

are subject to strict quality control. See Warranty. 

Safety Warnings – Guidelines: 

 

If instructions are not completely understood by operator or components are 
missing, contact 

FasTest

 

before attempting use of the connector. 

 

Application Safety: All 

FasTest 

products have been designed with safety in mind, 

however, it is the responsibility of the products users to design each process in 
such a way to avoid mishaps that can cause physical hazard or property loss. 
Secondary restraints such as safety chains, shields, cages or fixtures are all good 
choices depending on the application. 

FasTest

 can recommend or assist you in 

clarifying potential hazards of your application. 

 

FasTest 60/70

 Connectors are not internally valved, and will not prevent loss of 

media when disconnected. Do not attempt to disconnect unless safe conditions 
are met. 

 

FasTest 60/70

 Connectors must only be used with test pieces of a specific size 

as indicated by the part number. Improper use could cause separation of the 
connector from the test piece resulting in physical harm or damage. 

FasTest, Inc. Product Warranty

 

FasTest, Inc. warrants its products against defects of workmanship and/or material for 1 year from the date of the sale 
by FasTest, Inc.  This warranty is void if the product is misused, tampered with or used in a manner that is not in 
accordance with FasTest, Inc. recommendations and/or instructions. FasTest, Inc. is not liable for consequential or 
other damages including, but not limited to, loss, damage, personal injury, or any other expense directly or indirectly 
arising  from  the use  of  or  inability  to  use  its  products either separately  or  in combination with  other products.  ALL 
OTHER  WARRANTIES  EXPRESSED  OR  IMPLIED,  WHETHER  ORAL  OR  WRITTEN,  INCLUDING  BUT  NOT 
LIMITED  TO  WARRANTIES  OR  MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE  ARE 
EXPRESSLY EXCLUDED. 
Remedy under this warranty is limited to replacement of the product or an account credit in the amount of the original 
selling price, at the option on FasTest, Inc.  All allegedly defective products must be returned prepaid transportation to 
FasTest, Inc. along with information describing the products performance, unless disposition in the field is authorized 
in writing by FasTest, Inc. 

60/70 Series Connectors with ICON™

 

Description: 

60/70 Series Connectors to Grip and Seal Male 

threads and Males Features with ICON™ CV04.

 

 

 
 

 

60/70 ICON™

 

Connectors provide a reliable leak-tight 

connection that grips and seals male threads and male features. 
 
Please thoroughly read and understand these operating 
instructions prior to operating the connector. The use of 
pressurized media for sealing and testing requires a thorough 
understanding of the 

FasTest 60/70

 Operating Instructions. 

 

 

ICON™ Analog and SSR Calibration 

 

Installation 

 

Mechcanical Operation 

 

Main Seal Replacement 

 

Connector Maintenance 

 

Safety Warnings – Guidelines 

 

GTEK AUTOMATION    26212 Dimension Drive, Suite 150    Lake Forest, CA  92630    Ph. 949-680-4242    www.gtek-automation.com

Reviews: