![Siemens SINAMICS S150 NEMA Operating Instructions Manual Download Page 812](http://html.mh-extra.com/html/siemens/sinamics-s150-nema/sinamics-s150-nema_operating-instructions-manual_381570812.webp)
Technical specifications
12.3 Technical specifications
Enclosed Drives
810
Operating Instructions, 12/2018, A5E36652151A
Table 12- 10 Cabinet units, 380 ... 480 V 3 AC, Part 3
Article no.
6SL3710- 7LE37-5AU3
7LE38-4AU3
7LE41-0AU3
Unit rating
- for I
L
at 50 Hz 400 V
1)
- for I
H
at 50 Hz 400 V
1)
- for I
L
at 60 Hz 460 V
2)
- for I
H
at 60 Hz 460 V
2)
kW
kW
HP
HP
400
315
600
500
450
400
700
600
560
450
800
700
Output current
- Rated current I
N A 3)
- Base load current I
L 4)
- Base load current I
H 5)
- Max. current I
max A
A
A
A
A
745
725
570
1087
840
820
700
1230
985
960
860
1440
Infeed/regenerative current
- Rated current I
N E 6)
- Maximum current I
max E
A
A
674
1118
759
1260
888
1477
Max. current requirement
- Auxiliary 24 V DC supply
A
Internal
Internal
Internal
Supply voltages
- Line voltage
- Line frequency
- Electronic power supply
V
ACrms
Hz
V
DC
380 V 3 AC -10% to 480 V 3 AC +10% (-15% < 1 min)
47 to 63 Hz
24 (20.4 to 28.8)
Power loss, max.
- at 50 Hz, 400 V
- at 60 Hz, 460 V
kW
kW
20.63
11.15
21.1
13.65
27.25
18.55
Cooling air requirement
CFM
m
3
/s
4153
1.96
4153
1.96
5509
2.6
Sound pressure level L
pA
(1 m) at 50/60 Hz
dB(A)
77/79
77/79
77/79
Power connection
- maximum
- fixing screw
3 x 1/0 AWG
to 500 kcmil
10)
--
8 x 500 kcmil
M12 (4 holes)
8 x 500 kcmil
M12 (4 holes)
Motor connection
- maximum
- fixing screw
4 x 500 kcmil
M12 (2 holes)
4 x 500 kcmil
M12 (2 holes)
6 x 500 kcmil
M12 (3 holes)
Protective conductor connection
Fixing screw
M12 (10 holes)
M12 (16 holes)
M12 (18 holes)
Max. motor cable length
shielded / unshielded
ft
m
990 / 1485
300 / 450
990 / 1485
300 / 450
990 / 1485
300 / 450
Dimensions (standard version)
Width x Height x Depth
inch
mm
86.6 x 94.5 x 23.6
2200 x 2400 x 600
86.6 x 94.5 x 23.6
2200 x 2400 x 600
110.2 x 94.5 x 23.6
2800 x 2400 x 600
Frame sizes
- Active Interface Module
- Active Line Module
- Motor Module
HI
HX
HX
HI
HX
HX
JI
JX
JX
Weight (without options), approx.
lb
kg
3816
1731
3920
1778
5309
2408
Fuse type per phase
7)
Rated current
Frame size acc. to IEC 60269
UL file no. E167357
A
3NE1448-2
850
3
3NE1334-2
2 x 500
2
3NE1436-2
2 x 630
3
Summary of Contents for SINAMICS S150 NEMA
Page 1: ......
Page 2: ......
Page 20: ...Table of contents Enclosed Drives 18 Operating Instructions 12 2018 A5E36652151A ...
Page 861: ......
Page 862: ......