Operation
6.9 Communication via PROFINET IO
Enclosed Drives
386
Operating Instructions, 12/2018, A5E36652151A
6.9.7
Support of I&M data sets 1...4
Identification & Maintenance (I&M)
I&M data records contain information for a standardized and simplified identification and
maintenance of PROFINET devices. I&M data sets 1...4 contain system-specific information,
such as the installation location and date. PROFINET supports I&M data sets 0...4.
I&M data sets 1...3 can be set with the SIMATIC Manager (STEP 7) and also with
HW Config (STEP 7).
I&M parameters
Table 6- 32 Parameter designation, assignment and meaning
I&M parameter
designation
Format
Size/
octets
Initialization
SINAMICS
parameters
Meaning
I&M 0:
IM_SUPPORTED
-
-
-
r8820[62,63] The parameter indicates which I&M data sets
are supported.
The value 0x1E indicates that I&M data sets
1...4 are available.
I&M 1:
TAG_FUNCTION
Visible
string
32
Space
0x20…0x20
p8806[0...31] Text that identifies the function or task of the
device.
I&M 1:
TAG_LOCATION
Visible
string
22
Space
0x20…0x20
p8806[32...53] Text that identifies the device location.
I&M 2:
INSTALLATION_
DATE
Visible
string
16
Space
0x20…0x7E
p8807[0...15] Text with the date of the installation or the
initial commissioning of the device. The
following date formats are supported:
•
YYYY-MM-DD
•
YYYY-MM-DD hh:mm
–
YYYY: Year
–
MM: Month 01...12
–
DD: Day 01...31
–
hh: Hours 00...23
–
mm: Minutes 00...59
The separators between the individual
specifications, i.e. hyphen '-', blank ' ' and
colon ':', must be entered.