Operation
6.9 Communication via PROFINET IO
Enclosed Drives
368
Operating Instructions, 12/2018, A5E36652151A
PROFINET IO with IRT (Isochronous Real Time)
Isochronous real time: Real time property of PROFINET IO where IRT telegrams are
transferred deterministically via planned communication paths in a defined sequence to
achieve the best possible synchronism and performance between the IO controller and IO
device (drive unit). IRT is also known as time-scheduled communication whereby knowledge
about the network structure (topology) is utilized. IRT requires special network components
that support planned data transfer.
SINAMICS cycle times of minimum 250
μ
s (on-board) / 500
μ
s (CBE20) and a jitter accuracy
of less than 1
μ
s can be achieved when this transmission method is implemented.
Figure 6-40 Bandwidth distribution/reservation, PROFINET IO
6.9.2.3
Addresses
MAC address
Every Ethernet and PROFINET interface is assigned a worldwide unique device identifier in
the factory. This 6-byte long device identifier is the MAC address. The MAC address is
divided up as follows:
●
3 bytes for the manufacturer's ID
●
3 bytes device identifier (consecutive number).
The MAC address is printed on a label (CBE20) or specified on the type plate (CU320-2 PN),
e.g.: 08-00-06-6B-80-C0.
The Control Unit CU320-2 PN has two onboard interfaces:
●
One Ethernet interface
●
A PROFINET interface with two ports
The two MAC addresses of the Ethernet and PROFINET interfaces are stamped on the type
plate.