
Functions, monitoring and protective functions
9.3 Drive functions
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
587
Diagnostics
From this menu item, under the "Service overview" tab, the operating state is displayed for
each drive object.
In addition, color coding is used to indicate as to whether a fault or alarm is active for the
particular drive object.
Under the "Tracefiles" tab, trace files are displayed that are located on the memory card in
the "USER/SINAMICS/DATA/TRACE" directory.
Messages and Logs
The diagnostics buffer is displayed on the "Diagbuffer" tab via this menu item.
The faults and warnings of the drive are shown on the "Alarms drive" tab. With the "Reset
alarms" button, you can reset the acknowledgeable faults.
Parameter
With this menu item, you can create and manage self-defined parameter lists. Up to
20 parameter lists with 40 parameters each can be managed.
For each parameter list access rights (read, write, modify) of the two users ("SINAMICS"
and "Administrator") can be defined separately.
The settings of the write and know-how protection also apply to the parameters when
accessing the web server.
The created parameter lists are saved on the memory card of the drive. Therefore, a
parameter selection performed once is retained for further access even after the drive is
switched off.
Manage config
Via this menu item, the user "Administrator" can upload and update firmware and project
files.
Files
Via this menu item, the user "Administrator" can load user-defined pages into the drive.
User's Area
Via this menu item, the user "Administrator" can open user-defined pages.
Summary of Contents for SINAMICS S150 NEMA
Page 1: ......
Page 2: ......
Page 20: ...Table of contents Enclosed Drives 18 Operating Instructions 12 2018 A5E36652151A ...
Page 861: ......
Page 862: ......