Operation
6.7 Communication according to PROFIdrive
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
347
Channel-related diagnostics
Channel-related diagnostics encompasses the following data:
Bit
7
6
5
4
3
2
1
0
Octet
Name
x
Header-
Byte
1
1)
0
1)
0 ... 63 (module number) including these bytes
x + 1
1
2)
1
2)
0 (no component assignment)
x + 2
0
3)
0
3)
Message classes:
2 Undervoltage
3 Overvoltage
9 Error
16 Hardware/software error
17 Line supply/filter faulted
18 DC-link overvoltage
19 Power electronics faulted
20 Electronic component overtemp.
21 Ground/phase fault detected
22 Motor overload
23 Commun. with controller faulted
24 Safety monit. Detected an error
25 Act. Position/speed value error
26 Internal communication faulted
27 Infeed faulted
28 Braking controller faulted
29 External signal state error
30 Application/function faulted
31 Parameterization/commiss. error
1)
≙
Channel-related diagnostics
2)
≙
Input/output
3)
≙
"Channel type "non specific"
System response
Only one signal is generated if channel-related diagnostics identifies several faults belonging
to the same message class at the same drive object.
Data sets DS0/DS1 and diagnostics alarm
The PROFIdrive message classes are transferred using diagnostic alarm DS0/DS1. All faults
are assigned channel 0. The drive objects are assigned using the slot number.