Electrical installation
4.9 Additional connections
Enclosed Drives
184
Operating Instructions, 12/2018, A5E36652151A
Notes
Note
Replacement fuses
The article numbers for spare fuses can be taken from the spare parts list supplied.
Note
Standards requirements
The integrated safety functions, starting from the Safety Integrated (SI) input terminals of the
SINAMICS components (Control Unit, Motor Module), satisfy the requirements according to
EN 61800-5-2, EN 60204-1, EN ISO 13849-1 Category 3 (formerly EN 954-1) for
Performance Level (PL) d and IEC 61508 SIL2.
With the Safe Brake Adapter (option K88), the requirements specified in EN 61800-5-2,
EN 60204-1, EN ISO 13849-1 Category 3 (formerly EN954-1) as well as for Performance
Level (PL) d and IEC 61508 SIL 2 are fulfilled.
Note
Safety Integrated Function Manual
A detailed description of the full functionality and handling of the Safety Integrated functions
can be found in the accompanying Function Manual. This manual is available as additional
documentation on the customer DVD supplied with the device.
4.9.30
Control Unit CU320-2 PN (option K95)
With Option K95, the cabinet unit contains a CU320-2 PN control unit, which handles the
communication and open-loop/closed-loop control functions.
A PROFINET interface is available for higher-level communication.