Functions, monitoring and protective functions
9.4 Extended functions
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
683
SET_O, RESET_O
Tasks SET_O and RESET_O allow up to two binary signals (output 1 or 2) to be
simultaneously set or reset. The number of the output (1 or 2) is specified bit-coded in the
task parameter.
The following parameters are relevant:
●
p2616[x]: Block number
●
p2622[x]: Task parameter = output (bit encoded):
0x1: Output 1
0x2: Output 2
0x3: Output 1 + 2
Possible continuation conditions are END, CONTINUE_ON-THE-FLY and
CONTINUE_WITH_STOP, and CONTINUE_EXTERNAL_WAIT.
The binary signals (r2683.10 (output 1) (or r2683.11 (output 2)) can be assigned to digital
outputs.
Any two of the SET_O, RESET_O and GOTO orders can be processed in an interpolation
cycle and a subsequent POSITION and WAIT order can be started.
Function diagram
FP 3616
Traversing blocks mode (r0108.4 = 1)
Parameters
•
p2616
EPOS traversing block, block number
•
p2617
EPOS traversing block, position
•
p2618
EPOS traversing block, velocity
•
p2619
EPOS traversing block, acceleration override
•
p2620
EPOS traversing block, delay override
•
p2621
EPOS traversing block, order
•
p2622
EPOS traversing block, order parameter
•
p2623
EPOS traversing block, order mode
•
p2625
BI: EPOS block selection, bit 0
•
p2626
BI: EPOS block selection, bit 1
•
p2627
BI: EPOS block selection, bit 2
•
p2628
BI: EPOS block selection, bit 3
•
p2629
BI: EPOS block selection, bit 4
•
p2630
BI: EPOS block selection, bit 5
Summary of Contents for SINAMICS S150 NEMA