9.3.25.14
Tolerance window and correction
Figure 9-14 Tolerance window and correction
9.3.25.15
Dependencies
The following functions for tolerant encoder monitoring can be freely combined.
●
Encoder track monitoring
–
p0405.2 "Track monitoring"
–
p0437.26 "Deselection, track monitoring"
–
F3x117 "Inversion signal A/B/R error"
●
Zero mark tolerance
–
p0430.21 "Zero mark tolerance"
–
p04680 "Zero mark monitoring tolerance permissible"
–
A3x400 "Alarm threshold zero mark distance error"
–
A3x401 "Alarm threshold zero mark failed"