6.4.1
"PROFIdrive" default setting
Requirements
The "PROFIdrive" default setting was chosen during commissioning:
•
STARTER (p0700):
"PROFIdrive"
•
AOP30 (p0700):
"5: PROFIdrive"
Command sources
Figure 6-9
Command sources – AOP30 <--> PROFIdrive
Priority
The command source priorities are shown in the diagram "Command sources - AOP30 <->
PROFIdrive".
Note
Emergency OFF signals
The emergency OFF and motor protection signals are always active (regardless of the
command source).
All supplementary setpoints are deactivated for LOCAL master control.