![Rohde & Schwarz FPL1000 Series User Manual Download Page 779](http://html.mh-extra.com/html/rohde-and-schwarz/fpl1000-series/fpl1000-series_user-manual_1477826779.webp)
Remote Commands
R&S
®
FPL1000
779
User Manual 1178.3370.02 ─ 03
Managing Limit Lines
Useful commands for managing limit lines described in the R&S
FPL1000 User Man-
ual:
●
MMEM:SEL[:ITEM]:LIN:ALL
●
MMEM:STOR:TYPE
Remote commands exclusive to managing limit lines:
.................................................................................... 779
........................................................................................779
...................................................................................... 780
.......................................................................................780
CALCulate<n>:LIMit<k>:TRACe<t>:CHECk
......................................................................780
.............................................................................................. 781
............................................................................................ 781
CALCulate<n>:LIMit<k>:ACTive?
This command queries the names of
all
active limit lines.
Suffix:
<n>, <k>
.
irrelevant
Return values:
<LimitLines>
String containing the names of all active limit lines in alphabeti-
cal order.
Example:
CALC:LIM:ACT?
Queries the names of all active limit lines.
Usage:
Query only
Manual operation:
See
CALCulate<n>:LIMit<k>:COPY
<Line>
This command copies a limit line.
Suffix:
<n>
.
<k>
Parameters:
<Line>
1 to 8
number of the new limit line
<name>
String containing the name of the limit line.
Example:
CALC:LIM1:COPY 2
Copies limit line 1 to line 2.
CALC:LIM1:COPY 'FM2'
Copies limit line 1 to a new line named FM2.
Setting Basic Spectrum RF Measurement Parameters