![Rohde & Schwarz FPL1000 Series User Manual Download Page 730](http://html.mh-extra.com/html/rohde-and-schwarz/fpl1000-series/fpl1000-series_user-manual_1477826730.webp)
Remote Commands
R&S
®
FPL1000
730
User Manual 1178.3370.02 ─ 03
CALCulate<n>:MARKer<m>:SGRam:SARea
<SearchArea>
CALCulate<n>:MARKer<m>:SPECtrogram:SARea
<SearchArea>
This command defines the marker search area for all spectrogram markers in the
channel setup.
Suffix:
<n>, <m>
.
irrelevant
Parameters:
<SearchArea>
VISible
Performs a search within the visible frames.
Note that the command does not work if the spectrogram is not
visible for any reason (e.g. if the display update is off).
MEMory
Performs a search within all frames in the memory.
*RST:
VISible
Manual operation:
See
CALCulate<n>:MARKer<m>:SGRam:XY:MAXimum[:PEAK]
CALCulate<n>:MARKer<m>:SPECtrogram:XY:MAXimum[:PEAK]
This command moves a marker to the highest level of the spectrogram.
Suffix:
<n>
.
<m>
Usage:
Event
CALCulate<n>:MARKer<m>:SGRam:XY:MINimum[:PEAK]
CALCulate<n>:MARKer<m>:SPECtrogram:XY:MINimum[:PEAK]
This command moves a marker to the minimum level of the spectrogram.
Suffix:
<n>
.
<m>
Usage:
Event
CALCulate<n>:MARKer<m>:SGRam:Y:MAXimum:ABOVe
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MAXimum:ABOVe
This command moves a marker vertically to the next lower peak level for the current
frequency.
The search includes only frames above the current marker position. It does not change
the horizontal position of the marker.
Setting Basic Spectrum RF Measurement Parameters