Child Node
Attribute
Value
Parameter Description
Mand.
ShortName
DL | UL
No
Reference-
Power
Yes
Method
TX Channel Power |
TX Channel Peak
Power
Yes
Reference-
Channel
<string>
No
Table 7-14: Attributes and child nodes of the PowerClass element
Child Node
Attribute
Value
Parameter description
Mand.
StartPower
Value
<power in dBm>
The start power must be equal
to the stop power of the previ-
ous power class. The Start-
Power value of the first range
is -200
Yes
Unit
dBm
Yes
InclusiveFlag
true
Yes
StopPower
Value
<power in dBm>
The stop power must be equal
to the start power of the next
power class. The StopPower
value of the last range is 200
Yes
Unit
dBm
InclusiveFlag
false
Yes
DefaultLimitFailMode
Absolute | Relative
| Absolute and Rel-
ative | Absolute or
Relative
Yes
Table 7-15: Attributes and child nodes of the Range element (normal ranges)
Child node
Attribute
Value
Parameter description
Mand.
Index
0…19
Indices are continuous and
have to start with 0
Yes
Name
<string>
Name of the range
Only if Referen-
ceChannel con-
tains a name and
the range is the
reference range
Short-
Name
<string>
Short name of the range
No
ChannelType
TX | Adjacent
Yes