Troubleshooting Hardware Faults Using Oracle ILOM
■
“Locator Indicator On” on page 42
■
“Over Temperature Condition” on page 42
■
■
■
■
“Fan Module Failure” on page 44
■
■
“Front Panel Lamp Test” on page 45
■
“Indicator Blink Rates” on page 46
Server Boot Process and Normal Operating State Indicators
A normal server boot process involves two indicators, the service processor (SP) indicator and
the System OK indicator. The process is described below:
1. When the AC power is applied to the server, the service processor (SP) boots. As the SP
boots, its indicator blinks at the slow blink rate and the System OK indicator is off. For
indicator blink rate information, see
“Indicator Blink Rates” on page 46
2. When the SP has successfully booted, the SP indicator is on steady and the System OK
indicator blinks at the single blink rate. This indicates that the server is in standby power
mode (see
3. When the server host is booting (full power applied), the System OK indicator blinks at the
fast blink rate and the SP indicator is on steady. Once the server has successfully booted, the
System OK indicator turns on steady.
In its normal operating state, the system OK indicator and SP indicator are on steady and
green.
Troubleshooting and Diagnostics
41
Summary of Contents for X5-4
Page 1: ...Oracle Server X5 4 Service Manual Part No E56396 03 December 2015 ...
Page 2: ......
Page 10: ...10 Oracle Server X5 4 Service Manual December 2015 ...
Page 14: ...14 Oracle Server X5 4 Service Manual December 2015 ...
Page 21: ...Server Subsystems Overview Two CPU Block Diagram Oracle Server X5 4 Overview 21 ...
Page 36: ...36 Oracle Server X5 4 Service Manual December 2015 ...
Page 68: ...68 Oracle Server X5 4 Service Manual December 2015 ...
Page 178: ...178 Oracle Server X5 4 Service Manual December 2015 ...
Page 272: ...272 Oracle Server X5 4 Service Manual December 2015 ...
Page 340: ...340 Oracle Server X5 4 Service Manual December 2015 ...