Install a Fan Module
Install a Fan Module
This procedure describes how to install a replacement fan module in the server.
Before You Begin
■
For serviceability considerations, see
“Component Serviceability” on page 70
.
■
For fan module designation information, see
“Component Designations” on page 73
.
■
For instructions on removing a fan, see
“Remove a Fan Module” on page 130
1.
If you are installing a replacement fan module for one that has failed, check the
indicator of the failed fan slot to ensure the fault indicator is no longer lit.
This is necessary to ensure the indicator status is cleared before you insert the new fan. See
“Fan Module Reference” on page 135
for fan module indicator locations.
2.
Orient the fan module so the connector on the bottom of the module is aligned
with the connector on the inside of the slot and all keying and labeling are
correctly positioned.
Servicing CRU Components
133