Replace the Fan Board (FRU)
Refer to the figure in step 4 to determine proper connections.
Note -
Any excess cable length should be in the PCIe card area to allow better air flow through
the disk backplane area.
11.
Reinstall the P0 MR0/MR1 memory risers you removed earlier.
“Install a Memory Riser Card” on page 152
.
12.
Prepare the server for operation.
“Prepare the Server for Operation” on page 259
.
Replace the Fan Board (FRU)
This section provides instructions for replacing the fan board.
When servicing the components in this section, unplug the AC power cords and use ESD
protection.
Before You Begin
For serviceability considerations, see
“Component Serviceability” on page 70
1.
Prepare the server for service.
“Prepare the Server for Cold Service” on page 94
2.
Remove all fan modules.
“Remove a Fan Module” on page 130
3.
Remove all memory risers.
“Remove a Memory Riser Card” on page 145
Servicing FRU Components