Remove a Heatsink and CPU (FRU)
Note -
Ensure that you use the correct CPU replacement tool. The correct tool has part number
G29477-002 affixed to the side, and it has a green label. However, the label color alone is not
an indicator of the correct tool. Verify that the part number is correct.
a.
Press down on the release button on top of the replacement tool.
This action opens the tool.
On one corner of the tool there is a label with a downward pointing triangle. Likewise,
the CPU is marked with a triangle on one of its corners. This is a key that aligns the tool
and the CPU with the CPU socket. The tool and the CPU are correctly positioned with the
socket when all of the triangles are aligned.
b.
Orient the bottom of the tool over the CPU, ensuring that the triangle on the
tool aligns with the triangle on the CPU.
c.
Lower the tool onto the CPU, ensuring that it sits evenly on the CPU.
d.
Push the release tab away from the center button.
This action is accompanied by a click sound as the tool closes and grabs the CPU.
Servicing FRU Components
191
Summary of Contents for X5-4
Page 1: ...Oracle Server X5 4 Service Manual Part No E56396 03 December 2015 ...
Page 2: ......
Page 10: ...10 Oracle Server X5 4 Service Manual December 2015 ...
Page 14: ...14 Oracle Server X5 4 Service Manual December 2015 ...
Page 21: ...Server Subsystems Overview Two CPU Block Diagram Oracle Server X5 4 Overview 21 ...
Page 36: ...36 Oracle Server X5 4 Service Manual December 2015 ...
Page 68: ...68 Oracle Server X5 4 Service Manual December 2015 ...
Page 178: ...178 Oracle Server X5 4 Service Manual December 2015 ...
Page 272: ...272 Oracle Server X5 4 Service Manual December 2015 ...
Page 340: ...340 Oracle Server X5 4 Service Manual December 2015 ...