Troubleshooting Hardware Faults Using Oracle ILOM
PSU Failure
For a server with one of its PSU's in a failed state, the amber Service Action Required and PS
REAR indicators are on steady. The green System OK indicator and the green SP indicator are
on steady. In addition, the Service Action Required indicator on the failed PSU, as seen from
the back of the system, will also light.
Memory Failure
For a server with a failure in the memory subsystem, the amber Service Action Required and
MEM TOP indicators are on steady. The green OK indicator and the green SP indicator are on
steady.
Troubleshooting and Diagnostics
43