Remove a Fan Module
1.
Prepare the server:
■
For hot service, see
“Prepare the Server for Hot Service” on page 93
.
■
“Prepare the Server for Cold Service” on page 94
.
2.
If necessary, slide the server partially out from the rack.
a.
At the back of the server, verify that the cables have sufficient length and
clearance to extend the server.
The cable management arm (CMA) that is supplied with the server is hinged to facilitate
extending the server to the maintenance position. However, ensure that the cables do not
impede the sliding movement and are not damaged or overextended by it.
b.
At the front of the server, release the slide rails by pushing the two green
latches inward.
3.
Identify the faulty fan module using the fan module indicators.
Servicing CRU Components
131