Remove a Heatsink and CPU (FRU)
“Prepare the Server for Cold Service” on page 94
2.
Identify the failed CPU.
“Locate a Failed Memory Riser Card, DIMM, or CPU” on page 86
.
3.
Remove the two memory riser cards associated with the failed CPU.
4.
Remove the heatsink:
a.
Unscrew the four Phillips screws from the heatsink.
Turn the screws alternately one and one half turns until they are fully removed.
A thermal compound applied to the top of the CPU facilitates heat transfer to the heatsink
and acts as an adhesive.