Locating a Failed Memory Riser Card, DIMM, or CPU
Callout
Description
1
Storage drive filler panels
2
Storage drives
Locating a Failed Memory Riser Card, DIMM, or CPU
This section describes the system and DIMM Fault Remind test circuits and provides a
procedure for using the circuits to locate faulty components:
■
“Fault Remind Circuits and Internal Fault Indicator Locations” on page 82
■
“DIMM Fault Remind Circuit Components” on page 85
■
“Locate a Failed Memory Riser Card, DIMM, or CPU” on page 86
Fault Remind Circuits and Internal Fault Indicator
Locations
This section describes the locations of the system Fault Remind circuit components:
■
“System Fault Remind Button and Charge Status Indicator” on page 83
■
“Memory Riser Card and CPU Fault Indicators” on page 83
■
“CPU Fault Indicators” on page 84
82
Oracle Server X5-4 Service Manual • December 2015
Summary of Contents for X5-4