Remove a Heatsink and CPU (FRU)
5.
Open the spring-loaded CPU load plate release levers by pushing them down
and moving them slightly toward the CPU socket and away from their retaining
clips
The levers are numbered by their required order of operation. The left-side lever (when viewed
from the front of the server) must be opened first.
6.
Rotate the levers to the fully-open position.
When the second lever is in its fully-open position, the load plate is unlocked.
7.
To open the load plate, lift the unhinged end to its fully-open position.
Caution -
Component damage. The pins of the CPU socket can be easily damaged. To remove
the CPU, use the correct CPU replacement tool.
8.
To remove the CPU, use the CPU replacement tool:
The tool is used to remove and install the CPU in the socket. The top side of the replacement
tool has a button in the center and a tab on one side. Pressing down on the button opens the tool.
Pressing the tab closes the tool (and releases the button).
190
Oracle Server X5-4 Service Manual • December 2015
Summary of Contents for X5-4
Page 1: ...Oracle Server X5 4 Service Manual Part No E56396 03 December 2015 ...
Page 2: ......
Page 10: ...10 Oracle Server X5 4 Service Manual December 2015 ...
Page 14: ...14 Oracle Server X5 4 Service Manual December 2015 ...
Page 21: ...Server Subsystems Overview Two CPU Block Diagram Oracle Server X5 4 Overview 21 ...
Page 36: ...36 Oracle Server X5 4 Service Manual December 2015 ...
Page 68: ...68 Oracle Server X5 4 Service Manual December 2015 ...
Page 178: ...178 Oracle Server X5 4 Service Manual December 2015 ...
Page 272: ...272 Oracle Server X5 4 Service Manual December 2015 ...
Page 340: ...340 Oracle Server X5 4 Service Manual December 2015 ...