Remove a Fan Module
The Service Action Required indicators are located on the fan module. A lit amber color
Service Action Required indicator identifies a faulty component. For more information, see
“Fan Module Reference” on page 135
4.
Lift the green handle on the fan module and use it to pull the module straight up
and out of the server.
Caution -
Component damage. Excessive movement or rocking of the fan module during
removal can cause damage to the internal connector on the fan module board. When removing a
fan module, do not rock it back and forth.
Next Steps
“Install a Fan Module” on page 133
132
Oracle Server X5-4 Service Manual • December 2015