Troubleshooting Hardware Faults Using Oracle ILOM
CPU Failure
For a server with a fault in the processor subsystem, the amber Service Action Required
and CPU TOP indicators are on steady. The activity of green OK indicator and the green SP
indicator vary depending on whether the server can boot successfully. The server might not be
able to boot out of standby power mode.
For indicator blink rate information, see
“Indicator Blink Rates” on page 46
Fan Module Failure
For a server with a fan module fault, the amber Service Action Required and the FAN TOP
indicators are on steady. The green OK indicator and the green SP indicator are on steady.
For more information on fan indicators, see
“Fan Module Reference” on page 135