XtraDrive User Manual
Appendix D
:
List of Parameters
D-14
D.5. Auxiliary Functions
The following list shows the available auxiliary functions.
Parameter Function
Fn000
Alarm traceback data display.
Fn001
Rigidity setting for online autotuning.
Fn002
JOG mode operation.
Fn003
Zero-point search mode.
Fn004 (Reserved
parameter).
Fn005
Parameter settings initialization.
Fn006
Alarm traceback data clear.
Fn007
Writing to EEPROM inertia ratio data obtained from online autotuning.
Fn008
Absolute encoder multi-turn reset and encoder alarm reset.
Fn009
Automatic tuning of analog (speed, torque) reference offset.
Fn00A
Manual adjustment of speed reference offset.
Fn00B
Manual adjustment of torque reference offset.
Fn00C
Manual zero-adjustment of analog monitor output.
Fn00D
Manual adjustment of analog monitor output gain.
Fn00E
Automatic adjustment of motor current detection signal offset.
Fn00F
Manual adjustment of motor current detection signal offset.
Fn010
Write protect setting (protects parameters from being changed).
Fn011
Motor model display.
Fn012
Software version display.
Fn013
Multi-Turn Limit Setting: Change when a Multi-Turn Limit Disagreement Alarm
(A.CC) occurs.
Fn014
Clear Option Unit Detection Alarm (A.E7).
D.6. Monitor Modes
The following list shows monitor modes available
Parameter
Content of Display
Unit
Remarks
Un000
Actual motor speed
rpm
—
Un001
Input speed reference
rpm
—
Un002
Internal torque reference
%
Value for rated torque
Un003
Rotation angle 1
pulse
Number of pulses from the origin
Un004
Rotation angle 2
degree Angle from the origin (electrical angle)
Un005
Input signal monitor
—
—
Un006 Output
signal
monitor
—
—
Un007
Input reference pulse speed
rpm
—
Un008*
Error counter value
reference
units
Amount of position error
Un009
Accumulated load rate
%
Value for the rated torque as 100%
Displays effective torque in 10s cycle.
Un00A
Regenerative load rate
%
Value for the processable regenerative
power as 100%
Displays effective torque in 10s cycle.
Un00B
Power consumed by DB
resistance
%
Value for the processable power when
dynamic brake is applied as 100%
Displays effective torque in 10s cycle.
Un00C
Input reference pulse counter
—
Displayed in hexadecimal.
Un00D
Feedback pulse counter
—
Displayed in hexadecimal.
*Not used in serial communication command.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......