XtraDrive User Manual
Chapter 3: Wiring
3-20
The following examples show how to select the pull-up resistor R1 so
the input current (I) falls between 7 and 15mA.
Application Examples
R1 =2.2k
Ω
with
V
CC
= 24V ±5%
R1 =1k
Ω
with
V
CC
= 12V ±5%
R1 =180
Ω
with
V
CC
= 5V ±5%
•
Open-collector Output, Example 2: Using a servo amplifier with an
internal 12V power supply
This circuit uses the 12V power supply built into the servo
amplifier. The input is not isolated in this case.
!
Sequence Input Circuit Interface
The sequence input circuit interface connects through a relay or open-
collector transistor circuit. Select a low-current relay; otherwise a faulty
contact will result.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......