XtraDrive User Manual
Chapter
9
:
Inspection, Maintenance, and Troubleshooting
9-5
!
A.04: Parameter Setting Error
Display and Outputs
Alarm Outputs
Alarm Code Output
ALO1 ALO2
ALO3
ALM Output
OFF OFF
OFF
OFF
Note:
OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
A
At power ON
A
A,B
Cause of the Problem
Solution
A
An out-of-range parameter was
previously set or loaded
Reset all parameters in the range.
Otherwise, reload the correct parameter.
B
Circuit board (1PWB) is defective.
Replace the servo amplifier.
!
A.05: Servomotor and Amplifier Combination Error
Display and Outputs
Alarm Outputs
Alarm Code Output
ALO1 ALO2
ALO3
ALM Output
OFF OFF
OFF
OFF
Note:
OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
A
At power ON
A
A,B
Cause of the Problem
Solution
A
The range of servomotor capacities
that can be combined has been
exceeded.
Replace the servomotor so that
an acceptable combination is
achieved.
B
Encoder parameters have not been
written properly.
Replace the servomotor.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......