Output Signal Monitor Display
7 6 5 4 3 2 1
Top: OFF ("H" level)
Bottom: ON ("L" level)
Number
LED Number
Output Terminal Name
Default Setting
1 (CN1-31,
-32)
ALM
2
SO1 (CN1-25, -26)
/COIN or /V-CMP
3
SO2 (CN1-27, -28)
/TGON
4
SO3 (CN1-29, -30)
/S-RDY
5 (CN1-37)
AL01
6 (CN1-38)
AL02
7 (CN1-39)
AL03
Note: Refer to
5.3.4 Output Circuit Signal Allocation
for details on output terminals.
Output signals are allocated as shown above and displayed on the panel
of the servo amplifier or the digital operator. They are indicated by the
ON/OFF status of the vertical parts of seven-segment displays located
in top and bottom rows. (The horizontal segments are not used here).
These vertical segments turn ON or OFF relative to the state of the
corresponding output signals (ON for “L” level and OFF for “H” level).
Example
•
When ALM signal operates (alarm at “H”)
7 6 5 4 3 2 1
The top segment of
number 1 is lit.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......