Noise on the Reference Input Line
If the reference input line is affected by noise, ground the 0V line (SG)
of the reference input line. If the main circuit wiring for the motor is
accommodated in a metal conduit, ground the conduit and its junction
box.
All grounds must be made to only one point in the system.
Using Noise Filters
Use a noise suppression filter to prevent noise generated by the power
supply line. Install a noise filter on the power supply line for peripheral
equipment as necessary.
The following table recommends noise filters for each servo amplifier
model.
Recommended Noise Filter
Voltage
Servo Amplifier Model
Model Manufacturer
XD - P3 to XD - 02
FN2070-6/07
XD - 04
FN2070-10/07
XD - 08
FN2070-16/07
Single-phase,
200V
XD -15
FN350-30/33
XD -10
FN258L-7/07
Three-phase,
400V
XD -20, 30
FN258L-16/07
Schaffner
Note: Filters manufactured by Schaffner.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......