5.2.7. Using Torque Control
The XtraDrive servo amplifier limits torque as shown below.
•
Level 1: Limits maximum output torque to protect equipment or
workpiece.
•
Level 2: Limits torque after the servomotor moves the equipment to
a specified position (external torque limit).
•
Level 3: Controls torque output rather than speed output.
•
Level 4: Switches between speed and torque control.
The following describes uses for levels 3 and 4 in the torque control
function.
Torque Control Selection
Set the following parameter to select the type of control described in
levels 3 and 4.
Parameter
Signal
Setting
Control Mode
Pn000.1
Control Method
Selection
Default Setting: 0
Speed/Torque
Control, Position
Control
For further explanation of settings, see
Appendix D.2 Switches
.
A torque reference is entered from the host controller to the servo
amplifier in order to control torque.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......