![background image](http://html1.mh-extra.com/html/omron/8u0108-e1-01/8u0108-e1-01_user-manual_742062221.webp)
XtraDrive User Manual
Chapter 7: Using the Panel Operator
7-30
7.2.9.
Initializing Parameter Settings
This function is used to reset all parameters to the default settings
(standard factory settings).
IMPORTANT
•
Initialize the parameter settings with the servo OFF.
•
After performing the procedure, cycle the power to reset all the parameters to the default
settings.
Follow the procedure below to initialize parameter settings.
1.
Press the MODE/SET key to select the Auxiliary Function mode.
2.
Press the Up Arrow or Down Arrow key to select parameter Fn005.
3.
Press the DATA/SHIFT key for a minimum of one second, and the
display will be as shown below.
4.
Press the MODE/SET key, and the display will be as shown below.
The parameters will be initialized.
Flashing during
initialization
End
Flashing for
one second
5.
Press the DATA/SHIFT key for a minimum of one second to return
to the Auxiliary Function mode display.
This completes the initialization of parameter settings.
Note: Parameters will not be initialized by pressing the DSPL/SET or MODE/SET key with the servo ON.
Turn the power OFF and then back ON after initialization.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......