3.1.2. Single-Phase 0.8kW 200V Main Circuit Specifications
XtraDrive
XD-08-MS
has been changed from three-phase specifications to single-
phase. Main circuit connection terminals (
L1
,
L2
,
L3
) remained.
These devices have terminal
B3
and internal regenerative resistor. Observe the
following points.
1. Connect main power supply shown below to
L1
and
L3
terminals. Power supply is
single-phase, 220 to 230 VAC +10% to –15%, 50/60Hz. If power supply of 187V
(-15% of 220V) or less is used, alarm A.41 indicating voltage shortage, may occur
when accelerating to max speed with max torque of motor.
2. Short-circuit
B2
and
B3
terminals using the internal regenerative resistor. If
capacity of the regenerative resistor is insufficient, remove the lead between
B2
and
B3
terminals and connect an external regenerative resistor unit to
B1
and
B2
terminals.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......