A.E7: Option Unit Detection Error
A.E7 occurs the first time the SGDH amplifier is used after
disconnecting an option unit. This alarm cannot be cleared with an
alarm reset; instead, clear it with function Fn014.
Display and Outputs
Alarm Outputs
Alarm Code Output
ALO1 ALO2
ALO3
ALM Output
ON ON
OFF
OFF
Note:
OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
When the control power is
turned ON after
disconnecting an option
unit.
When the control power
is turned ON with an
option unit connected.
A
D
Cause of the Problem
Solution
A
The SGDH amplifier is used
immediately after disconnection
of an option unit without clearing
the unit detector.
To use the SGDH amplifier after
disconnecting the option unit, execute
Fn014 (option unit detection result
clear), in the auxiliary function mode,
and then cycle the power.
B
Option unit connection is
defective.
Check and correct the connection.
C
Option unit is defective.
Replace the option unit.
D
Servo amplifier
Replace the servo amplifier.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......