XtraDrive User Manual
Chapter 3: Wiring
3-22
•
Connecting an optocoupler output circuit
An optocoupler output circuits are used for servo alarm, servo ready,
and other sequence output signal circuits.
Connect an optocoupler output circuit through a relay or line
receiver circuit.
Note:
The maximum allowable capacities for optocoupler output circuits are:
•
Voltage: 30V
DC
•
Current: 50mA
DC
•
Connecting two XtraDrives (master-slave mode)
Connect output of “master” XtraDrive to “slave” XtraDrive’s input.
•
Connecting an external load to XtraDrive’s output.
Maximum current: 50mA.