5.7.2. Configuring an Absolute Encoder
Select the absolute encoder’s application with the following parameter.
Parameter Signal
Setting
Control
Mode
Pn002.2
Absolute Encoder
Application
Setting Range: 0 or 1
Default Setting: 0
Speed/Torque
Control, Position
Control
Either “0” or “1” in the following table must be set in order to enable
the absolute encoder.
Pn002.2 Setting
Result
0
Uses the absolute encoder as an absolute encoder.
1
Uses the absolute encoder as an incremental encoder.
The following parameter is used to periodically clear the encoder’s
counter (return the setting to 0) after a designated ratio of motor to load
axis revolutions. This function is called the multi-turn limit.
Note:
The term
Multi-turn Limit
refers to the highest number of rotations the encoder’s counter will display
before returning the counter to 0.
Parameter Signal
Setting
Control
Mode
Pn205
Multi-turn Limit Setting
Setting Range: 0 to 65535
Default Setting: 65535
Speed/Torque
Control, Position
Control
•
When Pn205 is set to the default (65535), multi-turn data varies in
the range of
−
32768 to +32767.
•
With any other Pn205 value entered, data varies from 0 to the set
value.
Note:
To activate reassignment of this value, the user must first enter the change to the parameter, and then
cycle (turn OFF and then turn ON) the power.
Since the encoder’s multi-turn limit value is set by default to 65535, the
following alarm occurs if the servo amplifier’s power supply is cycled
(turned OFF and ON) after changing parameter Pn205:
Alarm Code Output
Alarm Display
ALO1
ALO2
ALO3
Description
A.CC O
X
O
Encoder multi-turn limit value does not
match with that of the servo amplifier.
Note:
O: ON (“L”) signal
X: OFF (“H”) signal
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......