XtraDrive User Manual
Chapter
5
: Parameter Settings and Functions
5-73
5.6.1. External
Regenerative
Resistor
When installing an external regenerative resistor, a parameter setting
must be changed as shown below.
Parameter
Signal
Setting (x 10W)
Description
Pn600
Regenerative
Resistor Capacity
Setting Range: 0 to maximum
Default Setting: 0
Speed/Torque Control,
Position Control
The default setting of “0” in the above table is the set value when the
servo amplifier’s built-in resistor is used or when a servo amplifier
without a built-in resistor is used.
When installing an external regenerative resistor, set the regenerative
resistor’s capacity (W).
Example:
When the external regenerative resistor’s actual consumable capacity is 100W, set the parameter to
“10” (10 x 10W = 100W)
Note: 1.
In general, when resistors for power are used at the rated load ratio, the resistor temperature increases
to between 200°C and 300°C. The resistors must be used at or below the rated values.
Check with the manufacturer for the resistor’s load characteristics. Use resistors at no more than 20% of
the rated load ratio with natural convection cooling, and no more than 50% of the rated load ratio with
forced air-cooling. Parameter Pn600 must be set for the derated resistor.
2.
Use of resistors with thermal switches is recommended as a safety precaution.
Connecting Regenerative Resistors
The method for connecting regenerative resistors is as follows.
Disconnect the wire between the servo amplifier’s B2 and B3 terminals
and connect an external regenerative resistor between the B1 and B2
terminals.
Regenerative resistor
B1
B2
XtraDrive
*The user m ust provide the regenerative resistor.
B3
Be sure to take out the lead wire
between the B2 and B3 terminals.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......