5-8
5.1.3. Limiting
Torque
The XtraDrive servo amplifier limits torque as follows:
•
Level 1: Limits maximum output torque to protect equipment or
workpiece.
•
Level 2: Limits torque after the servomotor moves the equipment to
a specified position (external torque limit).
•
Level 3: Always limits output torque rather than speed.
•
Level 4: Switches between speed and torque limit.
The application of level 1 and 2 in the torque limit function is described
below.
Setting Level 1: Internal Torque Limits
Maximum torque is limited to the values set in the following
parameters.
Parameter
Signal
Setting (%)
Control Mode
Pn402
Forward Torque Limit
Range: 0 to 800
Default Setting: 800
Speed/Torque
Control, Position
Control
Pn403
Reverse Torque Limit
Range: 0 to 800
Default Setting: 800
Speed/Torque
Control, Position
Control
Sets the maximum torque limits for forward and reverse rotation.
Used when torque must be limited due to equipment conditions.
The torque limit function always monitors torque and outputs the
signals below when the limit is reached.
Signal Description
/CLT
Generated when Pn50F.0 allocates an output terminal from SO1 to
SO3.
Monitor Mode (Un006)
Output signal monitor
Torque limits are specified as a percentage of the rated torque.
Note:
If the torque limit is set higher than the maximum torque of the servomotor, the maximum torque of the
servomotor is the limit.
Application Example: Equipment Protection
Torque limit
Motor
speed
Torque
Too small a torque limit will result in an
insufficient torque during acceleration and
deceleration
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......