Follow the procedure below to execute the origin search.
1.
Press the MODE/SET key to select the Auxiliary Function mode.
2.
Press the Up Arrow or Down Arrow key to select the parameter
Fn003.
3.
Press the DATA/SHIFT key for a minimum of one second, and the
display will be as shown below.
4.
Press the DSPL/SET key, and the display will change as shown
below. Now it is ready for executing the origin search.
5.
Hold down Up Arrow or Down Arrow key to execute the origin
search. When the parameter is set to Pn000.0 = 0 (default), pressing
the Up Arrow key will rotate the motor in forward direction.
Pressing the Down Arrow key will rotate the motor in reverse
direction. When the parameter is set to Pn000.0 = 1, the rotation of
the motor is reversed.
UP: Forward
DOWN: Reverse
Keeps flashing
until origin search
is completed.
6.
Press the DATA/SHIFT key for a minimum of one second to return
to the Auxiliary Function mode display.
This completes the origin search operation.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......