XtraDrive User Manual
Chapter 2: Installation
2-4
Servo Amplifier Orientation
Install the servo amplifier perpendicular to the wall so the front panels’
connectors faces outward.
Cooling
As shown in the figure above, allow sufficient space around each servo
amplifier for cooling by cooling fans or natural convection.
Side-by-side Installation
When installing servo amplifiers side by side as shown in the figure
above, allow at least 0.39in (10mm) between and at least 1.97in
(50mm) above and below each servo amplifier. Install cooling fans
above the servo amplifiers to avoid excessive temperature rise and to
maintain even temperature inside the control panel.
Environmental Conditions in the Control Panel
•
Ambient Temperature:
0 to 55°C
•
Humidity:
90%
RH
or
less
•
Vibration:
0.5
G
(4.9m/s
2
)
•
Condensation and Freezing:
None
•
Ambient Temperature for Long-term Reliability: 45°C max.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......