Checking the Motor Model
Set the parameter Fn011 to select the Motor Model Check mode. This
mode is used for motor maintenance and can also be used to check the
special (Y-specification) codes of the servo amplifiers.
Follow the procedure below to check the motor model.
1.
Press the MODE/SET key to select the Auxiliary Function mode.
2.
Press the Up Arrow or Down Arrow key to select the parameter
Fn011.
3.
Press the DATA/SHIFT key for a minimum of one second to
display the servomotor model and voltage code.
Voltage
Model
Voltage Servomotor
Model
Code Voltage
Code Servomotor
Model
00 100V
AC
or 140V
DC
00 SGMAH
01 200V
AC
or 280V
DC
01 SGMPH
02 400V
AC
or 560V
DC
02
SGMSH
03 SGMGH-
A (1500rpm)
04 SGMGH-
B (1000rpm)
05 SAGMDH
06 SGMUH
4.
Press the MODE/SET key to display the Servomotor capacity.
Capacity: Displayed value x10 (W )
In this example, the capacity is 100W .
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......