XtraDrive User Manual
Appendix D
:
List of Parameters
D-7
D.2. Switches
The following list shows the switches and their default settings.
Parameter
Digit
Place
Name
Setting
Description
Default
Setting
0
Sets CCW as forward direction.
0 Direction
Selection
1
Sets CW as forward direction (reverse
rotation mode).
0
0
Speed control (analog reference).
2
Torque control (analog reference).
3
Internal set speed control (contact
reference).
4
Internal set speed control (contact
reference)/Speed control (analog
reference).
6
Internal set speed control (contact
reference)/Torque control (analog
reference).
8
Position control (pulse train
reference)/Torque control
(analog reference).
9
Torque control (analog reference)/Speed
control (analog reference).
A
Speed control (analog reference)/Zero
clamp.
B
Position control (pulse train
reference)/Position control (Inhibit)
C
Position control (pulse train)
1 Control Method
Selection
D
Serial communication command
D
2 Axis Address
0 to F Sets servo amplifier axis address.
0
Pn00
0
F
unction Se
lec
tion Basic S
w
itches
3 Reserved
—
0
0
Stops the motor by applying dynamic brake
(DB).
1
Stops the motor by applying dynamic brake
(DB) and then releases DB.
0
Servo OFF or
Alarm Stop
Mode
2
Makes the motor coast to a stop state
without using the dynamic brake (DB).
0
0
Same setting as Pn001.0 (Stops the motor
by applying DB or by coasting.)
1
Sets the torque of Pn406 to the maximum
value, decelerates the motor to a stop, and
then sets it to servo lock state.
1 Overtravel
Stop Mode
2
Sets the torque of Pn406 to the maximum
value, decelerates the motor to a stop, and
then sets it to coasting state.
0
0
Not applicable to DC power input: Input AC
power supply through L1, L2, and (L3)
terminals.
2 AC/DC Power
Input Selection
1
Applicable to DC power input: Input DC
power supply through (+)1 and (-) terminals.
0
0
ALO1, ALO2, and ALO3 output only alarm
codes.
1
ALO1, ALO2, and ALO3 output both alarm
codes and warning codes. While warning
codes are output, ALM signal output
remains ON (normal state).
Pn00
1
F
unction Se
lec
tion App
licati
on
S
w
itch
es
3
Warning Code
Output
Selection
2
Uses absolute encoder as an absolute
encoder.
Uses multi-turn limit.
0
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......