XtraDrive User Manual
Chapter 7: Using the Panel Operator
7-23
Follow the procedure below to manually adjust the speed reference
offset.
1.
Press the MODE/SET key to select the Auxiliary Function mode.
2.
Press the Up Arrow or Down Arrow key to select the parameter
Fn00A.
3.
Press the DATA/SHIFT key for a minimum of one second, and the
display will be as shown below. The manual adjustment mode for
the speed reference offset will be entered.
4.
Turn ON the Servo ON (/S-ON) signal. The display will be as
shown below.
5.
Press the DATA/SHIFT key for less than one second to display the
speed reference offset value.
6.
Press the Up Arrow or Down Arrow key to adjust the offset value
(adjustment of the speed reference offset).
7.
Press the DATA/SHIFT key for less than one second to return to
the display shown in step 4 above .
8.
Press the DATA/SHIFT key to return to the Auxiliary Function
mode display.
This completes the manual speed reference offset adjustment.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......