XtraDrive User Manual
Chapter 7: Using the Panel Operator
7-15
Reference Pulse/Feedback Pulse Counter Monitor Display
The monitor display of the reference pulse counter and feedback pulse
counter is expressed in 32-bit hexadecimal.
The display procedure is as follows:
1.
Press the MODE/SET key to select the Monitor mode.
2.
Press the Up Arrow AND Down Arrow keys to select “Un00C” or
“Un00D”.
3.
Press the DATA/SHIFT key for a minimum of one second to
display the data for the monitor number selected in the step above.
4.
Press the Up Arrow or Down Arrow key to alternately display the
leftmost 16-bit data and rightmost 16-bit data.
Leftmost 16-bit Data
Rightmost 16-bit Data
5.
Press both the Up Arrow AND Down Arrow keys simultaneously
to clear the 32-bit counter data.
6.
Press the DATA/SHIFT key once more for at least one second to
return to the monitor number display.
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......