5.9.1.6. Profile Speed (Pn2A2, Pn2A3)
These parameters are used to define the default value of the profile
speed variable. This variable is used to reach a target within a minimum
period of time (set the time of movement to –1). The driver accelerates
until it reaches this profile speed.
Parameter Setting
Units
Default
Setting
Signal
Pn2A2
Setting range 0-65535
User Speed
0
Work speed
default
Pn2A3
Setting range 0-256
User
Speed*65536
0
Work speed
default
For example, for a profile speed of 200000 [Speed units], set the
following parameters:
•
Pn2A3 = integer part of 200000 / 65536 = 3
•
Pn2A2 = 200000 – 3 * 65536 = 3392
5.9.1.7. Profile
Acceleration (Pn2A4, Pn2A5)
These parameters are used to define the default value of the profile
acceleration variable. This variable is used in Position mode whenever
the motor accelerates.
Parameter Setting
Signal
Pn2A4
Setting range 0-65535
Default setting: 0
[User Acceleration units]
Work acceleration default
Pn2A5
Setting range 0-256
Default setting: 0
[User Acceleration units*65536]
Work acceleration default
For example, for a profile acceleration of 200000 [Acceleration units],
set the following parameters:
•
Pn2A4 = integer part of 200000/65536 = 3
•
Pn2A5 = 200000 – 3*65536 = 3392
5.9.1.8. Jerk Smoothing Time (Pn2A6)
This parameter is used to define the default value of the jerk smoothing
time variable. This variable is used to define the jerk smoothing time of
a movement, i.e., it uses an average filter on the command pattern. For
example, if the command pattern is a trapeze, it will make it a S-curve
pattern.
Parameter
Setting [micro sec]
Signal
Pn2A6
Setting range 0-65535
Default setting: 0
Work jerk smoothing time
default
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......