XtraDrive User Manual
Chapter
5
: Parameter Settings and Functions
5-70
Note:
*1 and *2 are output terminals allocated with parameter Pn 510.0.
Multiple signals allocated to the same output terminal follow Boolean OR logic. In order to use the
/WARN output signal alone, set other output signals to a value other than the one allocated to the
/WARN signal. See
5.3.4 Output Circuit Signal Allocation.
/WARN
Warning
output signal
SO1 (CN1-25, 26)
SO2 (CN1-27, 28)
SO3 (CN1-29, 30)
Pn50F.3
1
2
3
Output terminals
The following parameter is used to output warning details with an alarm
code.
Parameter Signal
Setting
Control
Mode
Pn001.3
Warning Code Output
Selection
Default Setting: 0
Speed/Torque
Control, Position
Control
Pn001.3 Setting
Result
0
Outputs alarm codes only for alarm codes ALO1,
ALO2 and ALO3.
1
Outputs both alarm and warning codes for alarm
codes ALO1, ALO2 and ALO3 and outputs an
alarm code when an alarm occurs.
The following warning codes are output in 3 bits.
Warning Code Output
Warning
Indication
ALO1 ALO2 ALO3
Warning Description
A.91
ON signal
(low level)
OFF signal
(high level)
OFF signal
(high level)
Overload
A.92
OFF signal
(high level)
ON signal
(low level)
OFF signal
(high level)
Regenerative overload
To use the /NEAR signal, an output terminal must be allocated with the
parameter below.
Parameter Signal
Setting
Control
Mode
Pn510
Output Signal
Selections 3
Default Setting: 0000
Position Control
Summary of Contents for 8U0108-E1-01
Page 4: ...iv This page intentionally left blank...
Page 6: ...vi This page intentionally left blank...
Page 12: ...XtraDrive User Manual Table of Contents Preface xii This page intentionally left blank...
Page 27: ...XtraDrive User Manual Chapter 3 Wiring 3 3 3 1 1 Single Phase 200V Main Circuit Specifications...
Page 29: ...XtraDrive User Manual Chapter 3 Wiring 3 5 3 1 3 Three phase 200V Main Circuit Specifications...
Page 30: ...XtraDrive User Manual Chapter 3 Wiring 3 6 3 1 4 Three Phase 400V Main Circuit Specifications...
Page 32: ...XtraDrive User Manual Chapter 3 Wiring 3 8 3 2 2 Three phase 1kW to 3kW 200V Models...
Page 33: ...XtraDrive User Manual Chapter 3 Wiring 3 9 3 2 3 Three phase 0 5kW to 3 0kW 400V Models...
Page 56: ...XtraDrive User Manual Chapter 3 Wiring 3 32 This page intentionally left blank...
Page 332: ......